500°C 等温线法折减混凝土宽度 (EN 1992-1-2)

  • 类型:属性
  • 版本1
  • 2026/11/21已审核

根据 EN 1992-1-2 附录 B.1 的 500°C 等温线法计算的两侧受火混凝土梁或柱折减有效宽度 bfi:bfi = b - 2 · a500。

bfi=b−2⋅a500\displaystyle b_{fi} = b - 2 \cdot a_{500}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

bfi

Try it

Unit system
bfi\displaystyle b_{fi} = 240 mm= (300 mm) - 2 · (30 mm)