EN 1992-1-2 부속서 B.1의 500°C 등온선법에 따른 양측면 화재 노출 콘크리트 보 또는 기둥의 저감 유효폭 bfi: bfi = b - 2 · a500.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 원래 단면 폭 | mm | ||
| 화재 노출면으로부터 500°C 등온선 깊이 | mm | ||
| 화재 시 저감 유효 콘크리트 폭 | mm | Result |
예제
= 300 mm · = 30 mm
= 240 mm
Standard and source
- Standard
- EN 1992-1-2:2004
- Result
- in mm
Reference to clause and equation, no standard text. The description is written in our own words.