采用有效抗弯刚度的组合柱弹性临界屈曲荷载:Ncr = π² · EIeff / L²。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 组合柱有效抗弯刚度 | kN·m² | ||
| 组合柱计算长度 | m | ||
| 弹性临界轴力 | kN | Result |
实例
= 77,015.2 kN·m² · = 4.5 m
= 37,535.4 kN
Standard and source
- Standard
- EN 1994-1-1:2004
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.