설계 · 복합

합성 기둥의 탄성 임계 축력 Ncr

  • 유형: 저항
  • 버전 1
  • 2026. 11. 13.에 검토됨

유효 휨 강성을 사용한 합성 기둥의 탄성 임계 좌굴 하중: Ncr = π² · EIeff / L².

Ncr=π2⋅EIeff/L2\displaystyle N_{\mathrm{cr}} = \pi ^2 \cdot EI_{\mathrm{eff}} / L^2
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

NcrL

Formula and quantities

SymbolNameUnitNote
EIeff\displaystyle EI_{\mathrm{eff}}합성 기둥의 유효 휨 강성kN·m²
L\displaystyle L합성 기둥의 좌굴 길이m
Ncr\displaystyle N_{\mathrm{cr}}탄성 임계 축력kNResult

예제

EIeff\displaystyle EI_{\mathrm{eff}} = 77,015.2 kN·m² · L\displaystyle L = 4.5 m

Ncr\displaystyle N_{\mathrm{cr}} = 37,535.4 kN

Standard and source

Result
Ncr\displaystyle N_{\mathrm{cr}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Ncr\displaystyle N_{\mathrm{cr}} = 37,536.3 kN= pi ^ 2 · (77,015.2 kN·m²) / (4.5 m) ^ 2

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

설계 › 복합에서 검색이 시작됩니다.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.