设计 · 砌体

砌体抗压强度标准值(普通砂浆)

  • 类型:属性
  • 版本1
  • 2026/11/13已审核

采用普通砂浆或轻质砂浆的砌体抗压强度标准值:fk = K · fb⁰.7 · fm⁰.3。

fk=K⋅fb0.7⋅fm0.3\displaystyle f_{k} = K \cdot f_{\mathrm{b}}^{0.7} \cdot f_{m}^{0.3}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
K\displaystyle K砌体经验系数–K\displaystyle K > 0
fb\displaystyle f_{\mathrm{b}}砌体块材标准化平均抗压强度N/mm²fb\displaystyle f_{\mathrm{b}} > 0
fm\displaystyle f_{m}砂浆抗压强度N/mm²fm\displaystyle f_{m} > 0
fk\displaystyle f_{k}砌体抗压强度标准值N/mm²Result

实例

K\displaystyle K = 0.55 · fb\displaystyle f_{\mathrm{b}} = 15 N/mm² · fm\displaystyle f_{m} = 5 N/mm²

fk\displaystyle f_{k} = 5.93359 N/mm² · Source: 手算

Scope and standard

符合 EN 1996-1-1 第 3.6.1.2 条的普通砂浆或轻质砂浆砌体。

Standard
EN 1996-1-1-2005-a1:2012,第3.6.1.2条,式(3.1)
Result
fk\displaystyle f_{k} in N/mm²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
fk\displaystyle f_{k} = 5.93359 N/mm²= 0.55 · ((15 N/mm²) / 1 [N/mm²]) ^ 0.7 · ((5 N/mm²) / 1 [N/mm²]) ^ 0.3 · 1 [N/mm²]

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

检索将在 设计 › 砌体 开始。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.