Resistencia característica a compresión de fábrica con mortero ordinario o aligerado: fk = K · fb⁰,7 · fm⁰,3.

fk=K⋅fb0.7⋅fm0.3\displaystyle f_{k} = K \cdot f_{\mathrm{b}}^{0.7} \cdot f_{m}^{0.3}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
K\displaystyle KConstante empírica de la fábrica–K\displaystyle K > 0
fb\displaystyle f_{\mathrm{b}}Resistencia media normalizada a compresión de las piezas de fábricaN/mm²fb\displaystyle f_{\mathrm{b}} > 0
fm\displaystyle f_{m}Resistencia a compresión del morteroN/mm²fm\displaystyle f_{m} > 0
fk\displaystyle f_{k}Resistencia característica a compresión de la fábricaN/mm²Result

Ejemplo resuelto

K\displaystyle K = 0,55 · fb\displaystyle f_{\mathrm{b}} = 15 N/mm² · fm\displaystyle f_{m} = 5 N/mm²

fk\displaystyle f_{k} = 5,93359 N/mm² · Source: Cálculo manual

Scope and standard

Fábrica con mortero ordinario o aligerado según EN 1996-1-1, apartado 3.6.1.2.

Standard
EN 1996-1-1-2005-a1:2012, cláusula 3.6.1.2, Ecu. (3.1)
Result
fk\displaystyle f_{k} in N/mm²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
fk\displaystyle f_{k} = 5,93359 N/mm²= 0,55 · ((15 N/mm²) / 1 [N/mm²]) ^ 0.7 · ((5 N/mm²) / 1 [N/mm²]) ^ 0.3 · 1 [N/mm²]

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

La búsqueda comienza en Diseño › Mampostería.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.