목재보 유효 전단 폭 bef
균열 영향을 고려한 목재보의 유효 폭: bef = kcr · b
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 전단 저항 균열 계수 | – | ||
| 단면 폭 | mm | ||
| 전단 유효 폭 | mm | Result |
예제
= 0.67 · = 140 mm
= 93.8 mm · Source: EN 1995-1-1:2004 식 (6.13a)
Scope and standard
EN 1995-1-1 6.1.7절에 따른 목재 부재 전단 설계
- Standard
- EN 1995-1-1:2004, 6.1.7 (2) 절, 식 (6.13a)
- Result
- in mm
Reference to clause and equation, no standard text. The description is written in our own words.