설계 · 조적
전단력을 받는 조적벽 압축부 길이
인장강도를 무시한 선형 응력분포 가정 시 압축역 길이: e <= l/6일 때 lc = l, e > l/6일 때 lc = 1.5 · (l - 2 · e).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 벽체 전체 길이 | mm | > 0 | |
| 면내 하중 편심 M_Ed / N_Ed | mm | ≥ 0 | |
| 벽체 압축 길이 | mm | Result |
Valid if
적용 예제
균열 없는 단면 e = 300 mm <= 3000/6
= 3,000 mm · = 300 mm
= 3,000 mm · Source: 수기 계산
균열 단면 l = 3000 mm, e = 800 mm
= 3,000 mm · = 800 mm
= 2,100 mm · Source: 수기 계산
Scope and standard
EN 1996-1-1 조항 6.2(2) (e < l / 2에 유효).
- Standard
- EN 1996-1-1-2005-a1:2012, 6.2 절
- Result
- in mm
Reference to clause and equation, no standard text. The description is written in our own words.