設計 · コンクリート構造
簡略引張定着長さ (ACI 318)
ACI 318-19 表25.4.2.3(SI)による十分な被り・間隔を有する異形鉄筋 No. 19(D20)以下の簡略引張定着長さ: ld = ((fy / MPa) · ψt · ψe) / (2.1 · λ · √(fc / MPa)) · db.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 鉄筋の規格降伏強度 | N/m² | ||
| 打設位置係数(1.0 または 1.3) | 1 | ||
| 被覆係数(1.0 無被覆) | 1 | ||
| 軽量コンクリート係数(普通コンクリートは 1.0) | 1 | ||
| コンクリートの設計基準圧縮強度 | N/m² | ||
| 鉄筋の公称径 | mm | ||
| 引張定着長さ | mm | Result |
例題
= 420,000,000 N/m² · = 1 1 · = 1 1 · = 1 1 · = 28,000,000 N/m² · = 16 mm
= 604.74 mm
Standard and source
- Standard
- ACI 318-19
- Result
- in mm
Reference to clause and equation, no standard text. The description is written in our own words.