EN 1992-1-1 第 7.4.2 条 (2) によるスパン・せい比計算の基準鉄筋比: ρ0 = 10⁻³ · √(fck)。

ρ0=10−3⋅fck\displaystyle \rho_{0} = 10^{-3} \cdot \sqrt{f_{ck}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fck

Formula and quantities

SymbolNameUnitNote
fck\displaystyle f_{ck}コンクリートの基準円柱圧縮強度N/m²
ρ0\displaystyle \rho_{0}基準鉄筋比1Result

例題

fck\displaystyle f_{ck} = 25,000,000 N/m²

ρ0\displaystyle \rho_{0} = 0.005 1 · Source: 1992-1-1:2004 第7.4.2条(2)

Scope and standard

EN 1992-1-1 に準拠した鉄筋コンクリート梁およびスラブ。

Standard
EN 1992-1-1:2004、7.4.2 (2)項
Result
ρ0\displaystyle \rho_{0} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ρ0\displaystyle \rho_{0} = 0.005 1= 0.001 · sqrt((25,000,000 N/m²) / 1 [MPa])