設計 · コンクリート構造
帯鉄筋柱の最大設計軸耐力 (ACI 318)
ACI 318-19 表22.4.2.1による非プレストレスト帯鉄筋コンクリート柱の最大設計軸圧縮耐力: Pd = φ · 0.80 · (0.85 · fc · (Ag - Ast) + fy · Ast).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 帯鉄筋圧縮部材の強度低減係数(0.65) | 1 | ||
| コンクリートの設計基準圧縮強度 | N/m² | ||
| コンクリート全断面積 | mm² | ||
| 軸方向鉄筋の総断面積 | mm² | ||
| 軸方向鉄筋の規格降伏強度 | N/m² | ||
| 最大設計軸耐力 | kN | Result |
例題
= 0.65 1 · = 35,000,000 N/m² · = 160,000 mm² · = 2,400 mm² · = 420,000,000 N/m²
= 2,962.23 kN
Standard and source
- Standard
- ACI 318-19
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › コンクリート構造で開始されます。
Miaknows the formula catalog and asks for what is missing.