設計 · 組積造構造
組積造壁の単位長さあたり設計鉛直耐力
無筋組積造壁の単位長さあたり設計鉛直耐力:NRd = Φ · t · fd。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 耐力低減係数(Phi_i と Phi_m の最小値) | – | ≥ 0, ≤ 1 | |
| 組積造壁の厚さ | mm | > 0 | |
| 組積造の設計圧縮強度 | N/mm² | > 0 | |
| 単位長さあたり設計鉛直耐力 | kN/m | Result |
例題
= 0.65 · = 240 mm · = 3 N/mm²
= 468 kN/m · Source: 手計算
Scope and standard
EN 1996-1-1 条項 6.1.2.1 に基づく鉛直荷重下の無筋組積造壁。
- Standard
- EN 1996-1-1-2005-a1:2012、6.1.2.1項、式 (6.2)
- Result
- in kN/m
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 組積造構造で開始されます。
Miaknows the formula catalog and asks for what is missing.