Dimensionnement · Maçonnerie

Résistance de calcul sous charge verticale d'un mur en maçonnerie par mètre linéaire

  • Type : Résistance
  • Version 1
  • revue le 13/11/2026

Résistance verticale de calcul d'un mur en maçonnerie non armée par unité de longueur : NRd = Φ · t · fd.

NRd=Φ⋅t⋅fd\displaystyle N_{\mathrm{Rd}} = \Phi \cdot t \cdot f_{\mathrm{d}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

NRdtfdΦ

Formula and quantities

SymbolNameUnitNote
Φ\displaystyle ΦCoefficient de réduction de capacité (min de Phi_i et Phi_m)–Φ\displaystyle Φ ≥ 0, ≤ 1
t\displaystyle tÉpaisseur du mur en maçonneriemmt\displaystyle t > 0
fd\displaystyle f_{\mathrm{d}}Résistance de calcul à la compression de la maçonnerieN/mm²fd\displaystyle f_{\mathrm{d}} > 0
NRd\displaystyle N_{\mathrm{Rd}}Résistance verticale de calcul par unité de longueurkN/mResult

Exemple d’application

Φ\displaystyle Φ = 0,65 · t\displaystyle t = 240 mm · fd\displaystyle f_{\mathrm{d}} = 3 N/mm²

NRd\displaystyle N_{\mathrm{Rd}} = 468 kN/m · Source: Calcul manuel

Scope and standard

Murs en maçonnerie non armée sous charge verticale selon EN 1996-1-1, article 6.1.2.1.

Standard
EN 1996-1-1-2005-a1:2012, paragraphe 6.1.2.1, Eq. (6.2)
Result
NRd\displaystyle N_{\mathrm{Rd}} in kN/m

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
NRd\displaystyle N_{\mathrm{Rd}} = 468 kN/m= 0,65 · (240 mm) · (3 N/mm²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

La recherche commence dans Dimensionnement › Maçonnerie.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.