設計 · コンクリート構造
RC柱の火災時設計軸耐力 (EN 1992-1-2)
EN 1992-1-2 附属書B.1による低減コンクリート断面を用いた火災時鉄筋コンクリート柱の設計軸圧縮耐力: NRdfi = Acfi · fcdfi + As · fsdfi.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 低減有効コンクリート断面積 | mm² | ||
| 火災時コンクリートの設計圧縮強度 | N/m² | ||
| 軸方向鉄筋の総断面積 | mm² | ||
| 火災時鉄筋の設計降伏強度 | N/m² | ||
| 火災時設計軸耐力 | kN | Result |
例題
= 100,000 mm² · = 30,000,000 N/m² · = 2,400 mm² · = 300,000,000 N/m²
= 3,720 kN
Standard and source
- Standard
- EN 1992-1-2:2004
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › コンクリート構造で開始されます。
Miaknows the formula catalog and asks for what is missing.