設計 · コンクリート構造

RC梁の火災時設計曲げ耐力 (EN 1992-1-2)

  • タイプ:耐力
  • バージョン1
  • 2026/11/21にレビュー済み

EN 1992-1-2 附属書B.1 / 附属書Eによる単鉄筋コンクリート断面の火災時設計曲げ耐力: MRdfi = As · fsdfi · zfi.

MRd,fi=As⋅fsd,fi⋅zfi\displaystyle M_{\mathrm{Rd},fi} = A_{s} \cdot f_{sd,fi} \cdot z_{fi}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

zfiAsMRdfi

Formula and quantities

SymbolNameUnitNote
As\displaystyle A_{s}引張鉄筋の断面積mm²
fsdfi\displaystyle f_{sdfi}火災温度下における鉄筋の設計降伏強度N/m²
zfi\displaystyle z_{fi}火災時応力中心距離mm
MRdfi\displaystyle M_{Rdfi}火災時設計曲げ耐力kNmResult

例題

As\displaystyle A_{s} = 1,200 mm² · fsdfi\displaystyle f_{sdfi} = 390,000,000 N/m² · zfi\displaystyle z_{fi} = 450 mm

MRdfi\displaystyle M_{Rdfi} = 210.6 kNm

Standard and source

Result
MRdfi\displaystyle M_{Rdfi} in kNm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
MRdfi\displaystyle M_{Rdfi} = 210.6 kNm= (1,200 mm²) · (390,000,000 N/m²) · (450 mm)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › コンクリート構造で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.