設計 · 複合構造

鋼材寄与率 δ

  • タイプ:特性値
  • バージョン1
  • 2026/11/13にレビュー済み

合成柱の全塑性耐力に対する構造用鋼材の塑性耐力の比(簡易法では 0.2 <= delta <= 0.9):δ = (Aa · fyd) / Npl,Rd。

δ=(Aa⋅fyd)/Npl,Rd\displaystyle \delta = (A_{a} \cdot f_{yd}) / N_{\mathrm{pl},\mathrm{Rd}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

δNplRd

Formula and quantities

SymbolNameUnitNote
Aa\displaystyle A_{a}形鋼の断面積cm²
fyd\displaystyle f_{yd}構造用鋼材の設計降伏強度N/m²
Npl,Rd\displaystyle N_{\mathrm{pl},\mathrm{Rd}}合成柱の設計塑性耐力kN
δ\displaystyle \delta鋼材寄与率1Result

例題

Aa\displaystyle A_{a} = 118.4 cm² · fyd\displaystyle f_{yd} = 355,000,000 N/m² · Npl,Rd\displaystyle N_{\mathrm{pl},\mathrm{Rd}} = 7,247.3 kN

δ\displaystyle \delta = 0.58

Standard and source

Result
δ\displaystyle \delta in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
δ\displaystyle \delta = 0.579968 1= ((118.4 cm²) · (355,000,000 N/m²)) / (7,247.3 kN)