設計 · 複合構造
合成柱の軸方向座屈検定比 ηN
純軸圧縮を受ける合成柱の照査:ηN = NEd / (χ · Npl,Rd)。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 設計軸圧縮力 | kN | ||
| 該当する座屈曲線に対する座屈低減係数 | 1 | ||
| 設計塑性圧縮耐力 | kN | ||
| 軸方向座屈検定比 | 1 | Result |
例題
= 3,800 kN · = 0.85 · = 7,247 kN
= 0.617
Standard and source
- Standard
- EN 1994-1-1:2004
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.