Actions and loads · Traffic loads
Expansion joint fatigue amplification factor Δφ,fat (EN 1991-2)
Additional dynamic amplification factor for fatigue assessment near road bridge expansion joints (distance D <= 6 m) according to EN 1991-2 Clause 4.6.1(6) Eq. (4.7): Δφ,fat = 1.30 · (1 - D / 26).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Distance of cross-section from expansion joint in m (<= 6) | 1 | ||
| Additional fatigue amplification factor (>= 1.0) | 1 | Result |
Worked examples
At expansion joint D=0
= 0
= 1.3
At D=5 m
= 5
= 1.05
Standard and source
- Standard
- EN 1991-2:2003, clause 4.6.1, Eq. (4.7)
- Result
- in 1