하중 및 작용 · 교통 하중
신축이음부 피로 증폭계수 Δφ,fat (EN 1991-2)
EN 1991-2 제4.6.1(6)절 식 (4.7)에 따른 도로교 신축이음부 부근(거리 D <= 6 m) 피로평가용 추가 동적증폭계수: Δφ,fat = 1.30 · (1 - D / 26).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 신축이음부로부터 단면까지의 거리 m (<= 6) | 1 | ||
| 추가 피로 증폭계수 (>= 1.0) | 1 | Result |
적용 예제
At expansion joint D=0
= 0
= 1.3
At D=5 m
= 5
= 1.05
Standard and source
- Standard
- EN 1991-2:2003, 4.6.1 절, 식 (4.7)
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
하중 및 작용 › 교통 하중에서 검색이 시작됩니다.
Miaknows the formula catalog and asks for what is missing.