Design · Timber

Fastener double shear capacity Mode k Fv,Rk

  • Type: Resistance
  • Version 1
  • reviewed on 11/10/2026

Characteristic load-carrying capacity per shear plane for double shear timber connection Mode k according to EN 1995-1-1 eq. 8.7k: Fv,Rk = 1.15 · √(2 · β / (1 + β)) · √(2 · My,Rk · fh,1,k · d).

Fv,Rk=1.15⋅2⋅β/(1+β)⋅2⋅My,Rk⋅fh,1,k⋅d\displaystyle F_{v,Rk} = 1.15 \cdot \sqrt{2 \cdot \beta / (1 + \beta )} \cdot \sqrt{2 \cdot M_{y,Rk} \cdot f_{h,1,k} \cdot d}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

FvRkdfh1kMyRk

Formula and quantities

SymbolNameUnitNote
β\displaystyle \betaRatio of embedment strengths1
My,Rk\displaystyle M_{y,Rk}Yield moment of fastenerkNm
fh,1,k\displaystyle f_{h,1,k}Embedment strength in side memberN/m²
d\displaystyle dFastener diametermm
Fv,Rk\displaystyle F_{v,Rk}Characteristic capacity Mode kkNResult

Worked example

β\displaystyle \beta = 1 · My,Rk\displaystyle M_{y,Rk} = 0.32 kNm · fh,1,k\displaystyle f_{h,1,k} = 24,000,000 N/m² · d\displaystyle d = 16 mm

Fv,Rk\displaystyle F_{v,Rk} = 18.01 kN

Standard and source

Result
Fv,Rk\displaystyle F_{v,Rk} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Fv,Rk\displaystyle F_{v,Rk} = 18.0282 kN= 1.15 · sqrt(2 · (1 1) / (1 + (1 1))) · sqrt(2 · (0.32 kNm) · (24,000,000 N/m²) · (16 mm))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Timber.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.