Design · Steel
Member stability interaction utilization (z-z)
Overall member stability interaction utilization about z-axis according to EN 1993-1-1 eq. 6.62: ηzz = NEd / Nb,z,Rd + kzy · My,Ed / Mb,Rd + kzz · Mz,Ed / Mc,z,Rd <= 1.0.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Design axial compressive force | kN | ||
| Design buckling resistance about z-axis | kN | ||
| Interaction factor k_zy | 1 | ||
| Design bending moment about y-axis | kNm | ||
| Design lateral-torsional buckling resistance | kNm | ||
| Interaction factor k_zz | 1 | ||
| Design bending moment about z-axis | kNm | ||
| Design section bending resistance about z-axis | kNm | ||
| Member stability utilization ratio (z-z) | 1 | Result |
Worked example
= 80 kN · = 320 kN · = 0.65 · = 50 kNm · = 150 kNm · = 1.15 · = 8 kNm · = 40 kNm
= 0.697
Standard and source
- Standard
- EN 1993-1-1:2005
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.