Design · Steel

Modified fatigue reference strength Δσ,C,red (EN 1993-1-9)

  • Type: Property
  • Version 1
  • reviewed on 11/24/2026

Fatigue reference strength reduced by the plate thickness size-effect factor ks according to EN 1993-1-9 Clause 7.2.1: ΔσC,red = ks · ΔσC.

ΔσC,red=ks⋅ΔσC\displaystyle \Delta\sigma_{\mathrm{C},red} = k_{s} \cdot \Delta\sigma_{\mathrm{C}}
  • EN 1993-1-9:2005
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

ΔσCΔσC,redks

Formula and quantities

SymbolNameUnitNote
ks\displaystyle k_{s}Size-effect reduction factor1
ΔσC\displaystyle \Delta\sigma_{\mathrm{C}}Detail category reference fatigue strength at 2 million cyclesN/m²
ΔσC,red\displaystyle \Delta\sigma_{\mathrm{C},red}Modified reference fatigue strengthN/m²Result

Worked example

ks\displaystyle k_{s} = 0.91 · ΔσC\displaystyle \Delta\sigma_{\mathrm{C}} = 80,000,000 N/m²

ΔσC,red\displaystyle \Delta\sigma_{\mathrm{C},red} = 72,800,000 N/m²

Standard and source

Standard
EN 1993-1-9:2005
Result
ΔσC,red\displaystyle \Delta\sigma_{\mathrm{C},red} in MPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ΔσC,red\displaystyle \Delta\sigma_{\mathrm{C},red} = 72,800,000 N/m²= (0.91 1) · (80,000,000 N/m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Steel.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.