Design · Steel

Member interaction factor kyy (Method 2)

  • Type: Coefficient
  • Version 1
  • reviewed on 11/10/2026

Interaction factor kyy for member stability under bending and axial compression according to EN 1993-1-1 Annex B Table B.1: kyy = Cmy · (1 + (λ̄y - 0.2) · NEd / Nb,y,Rd).

kyy=Cmy⋅(1+(λbar,y−0.2)⋅NEd/Nb,y,Rd)\displaystyle k_{yy} = C_{my} \cdot (1 + (\lambda _{bar,y} - 0.2) \cdot N_{\mathrm{Ed}} / N_{\mathrm{b},y,\mathrm{Rd}})
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

λy

Formula and quantities

SymbolNameUnitNote
Cmy\displaystyle C_{my}Equivalent uniform moment factor C_my1
λˉy\displaystyle \bar{\lambda}_{y}Non-dimensional slenderness about y-axis1
NEd\displaystyle N_{\mathrm{Ed}}Design axial compression forcekN
Nb,y,Rd\displaystyle N_{\mathrm{b},y,\mathrm{Rd}}Design buckling resistance about y-axiskN
kyy\displaystyle k_{yy}Interaction factor k_yy1Result

Worked example

Cmy\displaystyle C_{my} = 0.9 · λˉy\displaystyle \bar{\lambda}_{y} = 0.8 · NEd\displaystyle N_{\mathrm{Ed}} = 200 kN · Nb,y,Rd\displaystyle N_{\mathrm{b},y,\mathrm{Rd}} = 500 kN

kyy\displaystyle k_{yy} = 1.116

Standard and source

Result
kyy\displaystyle k_{yy} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
kyy\displaystyle k_{yy} = 1.116 1= (0.9 1) · (1 + ((0.8 1) - 0.2) · (200 kN) / (500 kN))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Steel.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.