Design · Steel

Class 1 slenderness limit for web in pure compression

  • Type: Coefficient
  • Version 1
  • reviewed on 11/9/2026

Limiting width-to-thickness ratio for Class 1 web element subjected to pure compression: (c/tw)_lim = 33 · epsilon.

(c/tw)lim=33⋅ε\displaystyle (c/t_{w})_{\mathrm{lim}} = 33 \cdot \varepsilon
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

(c/tw)lim

Formula and quantities

SymbolNameUnitNote
ε\displaystyle \varepsilonYield factor–
(c/tw)lim\displaystyle (c/t_{w})_{\mathrm{lim}}Limiting slenderness ratio–Result

Worked example

ε\displaystyle \varepsilon = 0.8136

(c/tw)lim\displaystyle (c/t_{w})_{\mathrm{lim}} = 26.8488 · Source: EN 1993-1-1:2005 Table 5.2

Scope and standard

Internal compression elements under uniform compression according to EN 1993-1-1, Table 5.2 (sheet 1).

Standard
EN 1993-1-1:2005, clause 5.5.2, Eq. Table 5.2 (sheet 1)
Result
(c/tw)lim\displaystyle (c/t_{w})_{\mathrm{lim}} (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

(c/tw)lim\displaystyle (c/t_{w})_{\mathrm{lim}} = 26.8488= 33 · 0.8136

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Steel.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.