Cut-off limit for direct stress ranges at 100 million cycles according to EN 1993-1-9 Clause 7.1(1): ΔσL = 0.549 · ΔσD.

ΔσL=0.549⋅ΔσD\displaystyle \Delta\sigma_{L} = 0.549 \cdot \Delta\sigma_{D}
  • EN 1993-1-9:2005
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

ΔσDΔσL

Formula and quantities

SymbolNameUnitNote
ΔσD\displaystyle \Delta\sigma_{D}Constant amplitude fatigue limitN/m²
ΔσL\displaystyle \Delta\sigma_{L}Fatigue cut-off limitN/m²Result

Worked example

ΔσD\displaystyle \Delta\sigma_{D} = 58,960,000 N/m²

ΔσL\displaystyle \Delta\sigma_{L} = 32,369,000 N/m²

Standard and source

Standard
EN 1993-1-9:2005
Result
ΔσL\displaystyle \Delta\sigma_{L} in MPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ΔσL\displaystyle \Delta\sigma_{L} = 32,369,000 N/m²= 0.549 · (58,960,000 N/m²)