設計 · 鋼構造

疲労打切り限界 Δσ,L (EN 1993-1-9)

  • タイプ:特性値
  • バージョン1
  • 2026/11/24にレビュー済み

EN 1993-1-9 第7.1(1)項による1億回繰返しにおける垂直応力範囲の打切り限界: ΔσL = 0.549 · ΔσD.

ΔσL=0.549⋅ΔσD\displaystyle \Delta\sigma_{L} = 0.549 \cdot \Delta\sigma_{D}
  • EN 1993-1-9:2005
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

ΔσDΔσL

Formula and quantities

SymbolNameUnitNote
ΔσD\displaystyle \Delta\sigma_{D}一定振幅疲労限度N/m²
ΔσL\displaystyle \Delta\sigma_{L}疲労打切り限界N/m²Result

例題

ΔσD\displaystyle \Delta\sigma_{D} = 58,960,000 N/m²

ΔσL\displaystyle \Delta\sigma_{L} = 32,369,000 N/m²

Standard and source

Standard
EN 1993-1-9:2005
Result
ΔσL\displaystyle \Delta\sigma_{L} in MPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ΔσL\displaystyle \Delta\sigma_{L} = 32,369,000 N/m²= 0.549 · (58,960,000 N/m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › 鋼構造で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.