Design · Connections

Fillet weld design shear strength fvw,d

  • Type: Resistance
  • Version 1
  • reviewed on 11/13/2026

Design shear strength of a steel fillet weld using the simplified method: fvw,d = (fu / √(3)) / (βw · γM2).

fvw,d=(fu/3)/(βw⋅γM2)\displaystyle f_{vw,\mathrm{d}} = (f_{u} / \sqrt{3}) / (\beta _{w} \cdot \gamma _{\mathrm{M2}})
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fufvwdβw

Formula and quantities

SymbolNameUnitNote
fu\displaystyle f_{u}Nominal ultimate tensile strength of weaker part joinedN/m²
βw\displaystyle \beta_{w}Correlation factor for steel grade1
γM2\displaystyle \gamma_{\mathrm{M2}}Partial factor for welded joints1
fvw,d\displaystyle f_{vw,\mathrm{d}}Design shear strength of fillet weldN/m²Result

Worked example

fu\displaystyle f_{u} = 510,000,000 N/m² · βw\displaystyle \beta_{w} = 0.9 · γM2\displaystyle \gamma_{\mathrm{M2}} = 1.25

fvw,d\displaystyle f_{vw,\mathrm{d}} = 261,730,000 N/m²

Standard and source

Result
fvw,d\displaystyle f_{vw,\mathrm{d}} in MPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
fvw,d\displaystyle f_{vw,\mathrm{d}} = 261,732,000 N/m²= ((510,000,000 N/m²) / sqrt(3)) / ((0.9 1) · (1.25 1))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Connections.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.