Geotechnics · Bearing resistance
Tensile pile design resistance Rt,d
Design tensile resistance of an axially loaded pile: Rtd = Rtk / γst.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Characteristic tensile resistance of pile | kN | ||
| Partial safety factor for tensile pile resistance | – | ||
| Design tensile resistance of pile | kN | Result |
Worked example
= 500 kN · = 1.15
= 434.78 kN · Source: EN 1997-1:2004 clause 7.6.3.1
Scope and standard
Tension piles design according to EN 1997-1 Clause 7.6.3.1.
- Standard
- EN 1997-1:2004, clause 7.6.3.1, Eq. (7.15)
- Result
- in kN