Geotechnics · Bearing resistance
Drained bearing resistance per unit area R/A'
Drained bearing resistance from three terms: R / A' = c' · Nc · sc + q' · Nq · sq + 0.5 · gamma' · B' · Nγ · sgamma.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Effective cohesion | kN/m² | ||
| Bearing capacity factor for cohesion | – | ||
| Shape factor for cohesion | – | ||
| Effective overburden pressure at foundation base | kN/m² | ||
| Bearing capacity factor for surcharge | – | ||
| Shape factor for surcharge | – | ||
| Effective unit weight of soil below foundation | kN/m³ | ||
| Effective foundation width | m | ||
| Bearing capacity factor for self-weight | – | ||
| Shape factor for self-weight | – | ||
| Drained bearing resistance per unit area | kN/m² | Result |
Worked example
= 5 kN/m² · = 30.14 · = 1.35 · = 30 kN/m² · = 18.4 · = 1.33 · = 10 kN/m³ · = 2 m · = 20.09 · = 0.8
= 1,098.33 kN/m² · Source: EN 1997-1:2004 Annex D
Scope and standard
Shallow foundations on drained soils according to EN 1997-1, Annex D.
- Standard
- EN 1997-1:2004, clause D.4, Eq. (D.2)
- Result
- in kN/m²
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my memberwith Mia in CALC
- Compare with RFEM/RSTAB resultshand calculation versus model
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Geotechnics › Bearing resistance.
Miaknows the formula catalog and asks for what is missing.