Design · Concrete

Basic control perimeter for punching shear at rectangular column

  • Type: Definition
  • Version 1
  • reviewed on 11/9/2026

Basic control perimeter u1 at distance 2d from the loaded rectangular column face: u1 = 2 · (c1 + c2) + 4 · π · d.

u1=2⋅(c1+c2)+4⋅π⋅d\displaystyle u_{1} = 2 \cdot (c_{1} + c_{2}) + 4 \cdot \pi \cdot d
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

c1c2du1

Formula and quantities

SymbolNameUnitNote
c1\displaystyle c_{1}Column dimension in direction 1m
c2\displaystyle c_{2}Column dimension in direction 2m
d\displaystyle dMean effective depth of slabm
u1\displaystyle u_{1}Basic control perimetermResult

Worked example

c1\displaystyle c_{1} = 0.4 m · c2\displaystyle c_{2} = 0.4 m · d\displaystyle d = 0.2 m

u1\displaystyle u_{1} = 4.11327 m · Source: EN 1992-1-1:2004 Eq. (6.32)

Scope and standard

Flat slabs supported on rectangular columns at internal positions (EN 1992-1-1, clause 6.4.2).

Standard
EN 1992-1-1:2004, clause 6.4.2 (1), Eq. (6.32)
Result
u1\displaystyle u_{1} in m

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
u1\displaystyle u_{1} = 4.11327 m= 2 · ((0.4 m) + (0.4 m)) + 4 · pi · (0.2 m)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.