Design · Concrete
Basic control perimeter for punching shear at rectangular column
Basic control perimeter u1 at distance 2d from the loaded rectangular column face: u1 = 2 · (c1 + c2) + 4 · π · d.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Column dimension in direction 1 | m | ||
| Column dimension in direction 2 | m | ||
| Mean effective depth of slab | m | ||
| Basic control perimeter | m | Result |
Worked example
= 0.4 m · = 0.4 m · = 0.2 m
= 4.11327 m · Source: EN 1992-1-1:2004 Eq. (6.32)
Scope and standard
Flat slabs supported on rectangular columns at internal positions (EN 1992-1-1, clause 6.4.2).
- Standard
- EN 1992-1-1:2004, clause 6.4.2 (1), Eq. (6.32)
- Result
- in m
Reference to clause and equation, no standard text. The description is written in our own words.