Design · Concrete
Basic control perimeter for punching shear at circular column
Basic control perimeter u1 at distance 2d from a circular column with diameter D: u1 = π · (D + 4 · d).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Diameter of circular column | m | ||
| Mean effective depth of slab | m | ||
| Basic control perimeter | m | Result |
Worked example
= 0.4 m · = 0.2 m
= 3.76991 m · Source: EN 1992-1-1:2004 clause 6.4.2 (1)
Scope and standard
Flat slabs supported on circular columns at internal positions (EN 1992-1-1, clause 6.4.2).
- Standard
- EN 1992-1-1:2004, clause 6.4.2 (1)
- Result
- in m
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my dimensionsenter values, check the result
- Compare with a catalog sectionformula value and table value
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Concrete.
Miaknows the formula catalog and asks for what is missing.