Design · Concrete

Design value of concrete compressive strength

  • Type: Property
  • Version 1
  • reviewed on 11/9/2026

Design compressive strength of concrete according to EN 1992-1-1: fcd = αcc · fck / γc.

fcd=αcc⋅fck/γc\displaystyle f_{cd} = \alpha_{cc} \cdot f_{ck} / \gamma_{\mathrm{c}}

Call in Calculate modef_cd_ec2(alpha_cc; f_ck; gamma_c)

Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fcd

Formula and quantities

SymbolNameUnitNote
αcc\displaystyle \alpha_{cc}Coefficient for long-term effects on compressive strength–
fck\displaystyle f_{ck}Characteristic cylinder compressive strength of concreteN/mm²
γc\displaystyle \gamma_{\mathrm{c}}Partial factor for concrete–
fcd\displaystyle f_{cd}Design compressive strength of concreteN/mm²Result

Worked example

αcc\displaystyle \alpha_{cc} = 0.85 · fck\displaystyle f_{ck} = 30 N/mm² · γc\displaystyle \gamma_{\mathrm{c}} = 1.5

fcd\displaystyle f_{cd} = 17 N/mm² · Source: EN 1992-1-1:2004 clause 3.1.6

Scope and standard

Concrete structures designed to EN 1992-1-1, persistent and transient design situations.

Standard
EN 1992-1-1:2004, clause 3.1.6 (1), Eq. (3.15)
Result
fcd\displaystyle f_{cd} in N/mm²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
fcd\displaystyle f_{cd} = 17 N/mm²= 0.85 · (30 N/mm²) / 1.5

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.