Design · Composite
Plastic tensile force of slab reinforcement Ns
Design plastic tensile resistance of longitudinal reinforcement within the effective width in hogging bending regions: Ns = As · fsd.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Cross-sectional area of longitudinal reinforcement | cm² | ||
| Design yield strength of reinforcing steel | N/m² | ||
| Plastic tensile resistance of reinforcement | kN | Result |
Worked example
= 20 cm² · = 435,000,000 N/m²
= 870 kN
Standard and source
- Standard
- EN 1994-1-1:2004
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my memberwith Mia in CALC
- Compare with RFEM/RSTAB resultshand calculation versus model
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Composite.
Miaknows the formula catalog and asks for what is missing.