设计 · 木结构
木梁火灾下抗弯设计承载力 (EN 1995-1-2)
根据 EN 1995-1-2 第 4.2.2 条采用折减截面法的火灾下矩形木梁抗弯设计承载力:MRdfi = (bef · hef² / 6) · fmdfi。
- EN 1995-1-2:2004
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 木截面有效剩余宽度 | mm | ||
| 木截面有效剩余高度 | mm | ||
| 火灾下木材抗弯设计强度 | N/m² | ||
| 火灾下抗弯设计承载力 | kNm | Result |
实例
= 102 mm · = 351 mm · = 27,600,000 N/m²
= 57.81 kNm
Standard and source
- Standard
- EN 1995-1-2:2004
- Result
- in kNm
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
检索将在 设计 › 木结构 开始。
Miaknows the formula catalog and asks for what is missing.