设计 · 钢

内部受压板件屈曲折减系数 ρ (EN 1993-1-5)

  • 类型:属性
  • 版本1
  • 2026/11/24已审核

根据 EN 1993-1-5 第 4.4(2) 条内部受压板件(λp > 0.5 + √(0.085 - 0.055 · ψ))的 Winter 板屈曲折减系数 rho:ρ = (λp - 0.055 · (3 + ψ)) / λp²。

ρ=(λp−0.055⋅(3+ψ))/λp2\displaystyle \rho = (\lambda _{p} - 0.055 \cdot (3 + \psi )) / \lambda _{p}^2
  • EN 1993-1-5:2006
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

ψ

Formula and quantities

SymbolNameUnitNote
λp\displaystyle \lambda_{p}板件相对长细比1
ψ\displaystyle \psi边缘应力比 sigma_2 / sigma_11
ρ\displaystyle \rho板屈曲折减系数1Result

实例

λp\displaystyle \lambda_{p} = 1.2 · ψ\displaystyle \psi = 1

ρ\displaystyle \rho = 0.680556

Standard and source

Standard
EN 1993-1-5:2006
Result
ρ\displaystyle \rho in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

ρ\displaystyle \rho = 0.680556 1= ((1.2 1) - 0.055 · (3 + (1 1))) / (1.2 1)²

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

检索将在 设计 › 钢 开始。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.