设计 · 钢
内部受压板件屈曲折减系数 ρ (EN 1993-1-5)
根据 EN 1993-1-5 第 4.4(2) 条内部受压板件(λp > 0.5 + √(0.085 - 0.055 · ψ))的 Winter 板屈曲折减系数 rho:ρ = (λp - 0.055 · (3 + ψ)) / λp²。
- EN 1993-1-5:2006
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 板件相对长细比 | 1 | ||
| 边缘应力比 sigma_2 / sigma_1 | 1 | ||
| 板屈曲折减系数 | 1 | Result |
实例
= 1.2 · = 1
= 0.680556
Standard and source
- Standard
- EN 1993-1-5:2006
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
检索将在 设计 › 钢 开始。
Miaknows the formula catalog and asks for what is missing.