荷载与作用 · 偶然作用
防火分区开口系数 O (EN 1991-1-2)
根据 EN 1991-1-2 附录 A 式 (A.4) 用于参数化升温曲线的防火分区开口系数 O:O = (Av · √(heq / m)) / At。
- EN 1991-1-2:2002
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 所有墙面竖向开口总面积 | m² | ||
| 加权平均窗高 | m | ||
| 围护结构总表面积(包括开口在内的墙、顶棚、楼面) | m² | ||
| 开口系数(m^(1/2)) | 1 | Result |
实例
= 12 m² · = 2 m · = 300 m²
= 0.05657 1
Standard and source
- Standard
- EN 1991-1-2:2002
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.