设计 · 混凝土
混凝土割线弹性模量 Ecm
混凝土割线弹性模量,按 EN 1992-1-1 表 3.1: Ecm = 22 · (fcm / 10)⁰.3。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 混凝土平均抗压强度 (f_ck + 8 MPa) | N/m² | ||
| 混凝土割线弹性模量 | N/m² | Result |
实例
= 38,000,000 N/m²
= 32,836,600,000 N/m² · Source: EN 1992-1-1:2004 表 3.1
Scope and standard
按 EN 1992-1-1 的普通重力混凝土。
- Standard
- EN 1992-1-1:2004,第表 3.1条
- Result
- in GPa
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
检索将在 设计 › 混凝土 开始。
Miaknows the formula catalog and asks for what is missing.