设计 · 连接件

混凝土边缘破坏受剪偏心系数 ψec,V (EN 1992-4)

  • 类型:属性
  • 版本1
  • 2026/11/25已审核

根据 EN 1992-4 第 7.2.2.5 条式 (7.46) 边缘附近紧固件群承受偏心剪力的群锚效应系数:ψecV = 1 / (1 + 2 · eV / (3 · c1))。

ψecV=1/(1+2⋅eV/(3⋅c1))\displaystyle \psi _{ecV} = 1 / (1 + 2 \cdot e_{V} / (3 \cdot c_{1}))
  • EN 1992-4:2018
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

c1eVψecV

Formula and quantities

SymbolNameUnitNote
eV\displaystyle e_{V}剪力合力偏心距mm
c1\displaystyle c_{1}受力方向边距mm
ψecV\displaystyle \psi_{ecV}剪力偏心系数1Result

实例

eV\displaystyle e_{V} = 45 mm · c1\displaystyle c_{1} = 150 mm

ψecV\displaystyle \psi_{ecV} = 0.833333

Standard and source

Standard
EN 1992-4:2018
Result
ψecV\displaystyle \psi_{ecV} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ψecV\displaystyle \psi_{ecV} = 0.833333 1= 1 / (1 + 2 · (45 mm) / (3 · (150 mm)))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

检索将在 设计 › 连接件 开始。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.