根据 ACI 318-19 第 19.2.3.1 节(SI 单位)用于挠度和开裂弯矩计算的混凝土抗折强度:fr = 0.62 · λ · √(fc / MPa) · MPa。

fr=0.62⋅λ⋅fc′\displaystyle f_{r} = 0.62 \cdot \lambda \cdot \sqrt{f'_{\mathrm{c}}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fc

Formula and quantities

SymbolNameUnitNote
λ\displaystyle \lambda轻骨料混凝土修正系数(普通混凝土取 1.0)1
fc\displaystyle f_{\mathrm{c}}混凝土规定抗压强度N/m²
fr\displaystyle f_{r}抗折强度N/m²Result

实例

λ\displaystyle \lambda = 1 1 · fc\displaystyle f_{\mathrm{c}} = 28,000,000 N/m²

fr\displaystyle f_{r} = 3,280,700 N/m²

Standard and source

Standard
ACI 318-19
Result
fr\displaystyle f_{r} in MPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
fr\displaystyle f_{r} = 3,280,730 N/m²= 0.62 · (1 1) · sqrt((28,000,000 N/m²) / [MPa]) · [MPa]