设计 · 混凝土

火灾下钢筋设计强度 fsd,fi (EN 1992-1-2)

  • 类型:属性
  • 版本1
  • 2026/11/21已审核

根据 EN 1992-1-2 第 2.3 条式 (2.2) 的高温下钢筋设计屈服强度:fsdfi = (ks · fyk) / γMfi。

fsd,fi=ks(Θ)⋅fykγM,fi\displaystyle f_{sd,fi} = \frac{k_{s}(\Theta) \cdot f_{yk}}{\gamma_{M,fi}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fsdfi

Formula and quantities

SymbolNameUnitNote
ks\displaystyle k_{s}钢筋强度高温折减系数1
fyk\displaystyle f_{yk}钢筋特征屈服强度N/m²
γMfi\displaystyle \gamma_{Mfi}火灾下钢筋分项系数(通常取 1.0)1
fsdfi\displaystyle f_{sdfi}火灾下钢筋设计强度N/m²Result

实例

ks\displaystyle k_{s} = 0.78 1 · fyk\displaystyle f_{yk} = 500,000,000 N/m² · γMfi\displaystyle \gamma_{Mfi} = 1 1

fsdfi\displaystyle f_{sdfi} = 390,000,000 N/m²

Standard and source

Result
fsdfi\displaystyle f_{sdfi} in MPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
fsdfi\displaystyle f_{sdfi} = 390,000,000 N/m²= ((0.78 1) · (500,000,000 N/m²)) / (1 1)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

检索将在 设计 › 混凝土 开始。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.