4면 화재 시 목재 유효잔존단면적 (EN 1995-1-2)
EN 1995-1-2 제4.2.2절에 따른 4면 화재 노출 직사각형 목재 기둥의 유효잔존단면적: Aef = (b - 2 · def) · (h - 2 · def).
- EN 1995-1-2:2004
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 원래 목재 단면 폭 | mm | ||
| 원래 목재 단면 춤 | mm | ||
| 유효탄화깊이 | mm | ||
| 유효잔존단면적 | mm² | Result |
예제
= 240 mm · = 240 mm · = 49 mm
= 20,164 mm²
Standard and source
- Standard
- EN 1995-1-2:2004
- Result
- in mm²
Reference to clause and equation, no standard text. The description is written in our own words.