설계 · 목재
섬유방향 직각 압축 유효 접촉 길이 lef
하중 분포를 고려한 유효 지압 길이: lef = l + min(a; 30 mm) + min(l1; 30 mm)
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 실제 접촉 길이 | mm | ||
| 부재 단부로부터 거리 | mm | ||
| 인접 지압 거리 또는 돌출부 | mm | ||
| 유효 접촉 길이 | mm | Result |
예제
= 100 mm · = 40 mm · = 50 mm
= 160 mm · Source: EN 1995-1-1:2004 식 (6.4)
Scope and standard
EN 1995-1-1 6.1.5절에 따른 목재 접촉면
- Standard
- EN 1995-1-1:2004, 6.1.5 (1) 절, 식 (6.4)
- Result
- in mm
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
설계 › 목재에서 검색이 시작됩니다.
Miaknows the formula catalog and asks for what is missing.