설계 · 강재

무피복 강재 부재의 단면계수 Am/V (EN 1993-1-2)

  • 유형: 성질
  • 버전 1
  • 2026. 11. 21.에 검토됨

EN 1993-1-2 제4.2.5.1절에 따른 화재 노출 무피복 강재 부재의 단면계수 Am/V: Sf = Am / V.

AmV=AmV\displaystyle \frac{A_{m}}{V} = \frac{A_{m}}{V}
  • EN 1993-1-2:2005
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
Am\displaystyle A_{m}단위길이당 화재 노출 표면적 (가열 둘레)m
V\displaystyle V단위길이당 체적 (단면적)m²
Sf\displaystyle S_{f}단면계수 Am/Vm⁻¹Result

예제

Am\displaystyle A_{m} = 1.16 m · V\displaystyle V = 0.00538 m²

Sf\displaystyle S_{f} = 215.61 m⁻¹

Standard and source

Standard
EN 1993-1-2:2005
Result
Sf\displaystyle S_{f} in m⁻¹

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Sf\displaystyle S_{f} = 215.613 m⁻¹= (1.16 m) / (0.00538 m²)