設計 · 鋼構造

無被覆鋼部材の断面係数 Am/V (EN 1993-1-2)

  • タイプ:特性値
  • バージョン1
  • 2026/11/21にレビュー済み

EN 1993-1-2 第4.2.5.1項による火災にさらされる無被覆鋼部材の断面係数 Am/V: Sf = Am / V.

AmV=AmV\displaystyle \frac{A_{m}}{V} = \frac{A_{m}}{V}
  • EN 1993-1-2:2005
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
Am\displaystyle A_{m}単位長さあたりの加熱表面積(加熱周長)m
V\displaystyle V単位長さあたりの体積(断面積)m²
Sf\displaystyle S_{f}断面係数 Am/Vm⁻¹Result

例題

Am\displaystyle A_{m} = 1.16 m · V\displaystyle V = 0.00538 m²

Sf\displaystyle S_{f} = 215.61 m⁻¹

Standard and source

Standard
EN 1993-1-2:2005
Result
Sf\displaystyle S_{f} in m⁻¹

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Sf\displaystyle S_{f} = 215.613 m⁻¹= (1.16 m) / (0.00538 m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › 鋼構造で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.