설계 · 강재
단면의 소성 전단 저항 Vpl,Rd
단면의 설계 소성 전단 저항: Vpl,Rd = Av · (fy / √(3)) / γM0.
Call in Calculate modev_pl_rd_ec3(A_v; f_y; gamma_M0)
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 전단 단면적 | m² | ||
| 항복 강도 | N/mm² | ||
| 부분계수 | – | ||
| 소성 전단 저항 | kN | Result |
예제
= 0.002568 m² · = 235 N/mm² · = 1
= 348.43 kN · Source: EN 1993-1-1:2005 식 (6.18)
Scope and standard
EN 1993-1-1, 6.2.6절에 따른 전단 좌굴이 없는 단면.
- Standard
- EN 1993-1-1:2005, 6.2.6 (2) 절, 식 (6.18)
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Matching CALC skillEurocode 3에 따른 단일경간 강재 보
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
설계 › 강재에서 검색이 시작됩니다.
Miaknows the formula catalog and asks for what is missing.