설계 소성 전단내력 VRd

  • 유형: 저항
  • 버전 1
  • 2026. 11. 13.에 검토됨

비세장 알루미늄 단면의 설계 소성 전단내력: VRd = Av · fo / (√(3) · γM1).

VRd=Av⋅fo/(3⋅γM1)\displaystyle V_{\mathrm{Rd}} = A_{v} \cdot f_{o} / (\sqrt{3} \cdot \gamma _{\mathrm{M1}})
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

VRd+VRd-VRd

Formula and quantities

SymbolNameUnitNote
Av\displaystyle A_{v}단면의 전단면적cm²
fo\displaystyle f_{o}특성 0.2 % 내력N/m²
γM1\displaystyle \gamma_{\mathrm{M1}}단면 내력 부분안전계수1
VRd\displaystyle V_{\mathrm{Rd}}설계 소성 전단 저항력kNResult

예제

Av\displaystyle A_{v} = 12 cm² · fo\displaystyle f_{o} = 260,000,000 N/m² · γM1\displaystyle \gamma_{\mathrm{M1}} = 1.1

VRd\displaystyle V_{\mathrm{Rd}} = 163.75 kN

Standard and source

Result
VRd\displaystyle V_{\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
VRd\displaystyle V_{\mathrm{Rd}} = 163.758 kN= (12 cm²) · (260,000,000 N/m²) / (sqrt(3) · (1.1 1))