설계 · 알루미늄

설계 압축내력 Nc,Rd

  • 유형: 저항
  • 버전 1
  • 2026. 11. 13.에 검토됨

균일 축압축을 받는 알루미늄 단면의 설계 내력: Nc,Rd = Aeff · fo / γM1.

Nc,Rd=Aeff⋅fo/γM1\displaystyle N_{\mathrm{c},\mathrm{Rd}} = A_{\mathrm{eff}} \cdot f_{o} / \gamma _{\mathrm{M1}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

NcRd

Formula and quantities

SymbolNameUnitNote
Aeff\displaystyle A_{\mathrm{eff}}국부좌굴과 HAZ를 고려한 유효 단면적cm²
fo\displaystyle f_{o}특성 0.2 % 내력N/m²
γM1\displaystyle \gamma_{\mathrm{M1}}단면 내력 부분안전계수1
Nc,Rd\displaystyle N_{\mathrm{c},\mathrm{Rd}}설계 압축 저항kNResult

예제

Aeff\displaystyle A_{\mathrm{eff}} = 27 cm² · fo\displaystyle f_{o} = 260,000,000 N/m² · γM1\displaystyle \gamma_{\mathrm{M1}} = 1.1

Nc,Rd\displaystyle N_{\mathrm{c},\mathrm{Rd}} = 638.18 kN

Standard and source

Result
Nc,Rd\displaystyle N_{\mathrm{c},\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Nc,Rd\displaystyle N_{\mathrm{c},\mathrm{Rd}} = 638.182 kN= (27 cm²) · (260,000,000 N/m²) / (1.1 1)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

설계 › 알루미늄에서 검색이 시작됩니다.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.