설계 · 목재
목재 보의 화재 시 설계휨저항 (EN 1995-1-2)
EN 1995-1-2 제4.2.2절에 따른 저감단면법을 이용한 화재 시 직사각형 목재 보의 설계휨모멘트저항: MRdfi = (bef · hef² / 6) · fmdfi.
- EN 1995-1-2:2004
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 목재 단면의 유효잔존폭 | mm | ||
| 목재 단면의 유효잔존춤 | mm | ||
| 화재 시 목재 설계휨강도 | N/m² | ||
| 화재 시 설계휨모멘트저항 | kNm | Result |
예제
= 102 mm · = 351 mm · = 27,600,000 N/m²
= 57.81 kNm
Standard and source
- Standard
- EN 1995-1-2:2004
- Result
- in kNm
Reference to clause and equation, no standard text. The description is written in our own words.
Try it