설계 · 목재

목재 접합철물 축방향 설계저항 Fax,Rd (EN 1995-1-1)

  • 유형: 성질
  • 버전 1
  • 2026. 11. 25.에 검토됨

EN 1995-1-1 제2.4.1절에 따른 목재 접합철물의 설계 축방향 인발 또는 머리 관통저항: Fax,Rd = kmod · Fax,Rk / γM.

Fax,Rd=kmod⋅Fax,Rk/γM\displaystyle F_{ax,\mathrm{Rd}} = k_{mod} \cdot F_{ax,Rk} / \gamma _{M}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

FaxRd

Formula and quantities

SymbolNameUnitNote
kmod\displaystyle k_{mod}하중지속시간 및 함수율 수정계수1
Fax,Rk\displaystyle F_{ax,Rk}특성 축방향 저항kN
γM\displaystyle \gamma_{M}재료특성 부분안전계수 (일반적으로 1.3)1
Fax,Rd\displaystyle F_{ax,\mathrm{Rd}}설계 축방향 저항kNResult

예제

kmod\displaystyle k_{mod} = 0.8 · Fax,Rk\displaystyle F_{ax,Rk} = 6.7 kN · γM\displaystyle \gamma_{M} = 1.3

Fax,Rd\displaystyle F_{ax,\mathrm{Rd}} = 4.12308 kN

Standard and source

Result
Fax,Rd\displaystyle F_{ax,\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Fax,Rd\displaystyle F_{ax,\mathrm{Rd}} = 4.12308 kN= (0.8 1) · (6.7 kN) / (1.3 1)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

설계 › 목재에서 검색이 시작됩니다.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.