설계 · 강재
횡비틀림좌굴 설계 저항 모멘트 Mb,Rd
비지지 보의 횡비틀림좌굴 설계 저항 모멘트: Mb,Rd = χLT · Wy · fy / γM1.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 횡비틀림좌굴 저감계수 | – | ||
| 단면계수 | m³ | ||
| 항복 강도 | N/mm² | ||
| 부재 안정성에 대한 부분계수 | – | ||
| 설계 좌굴 저항 모멘트 | Nm | Result |
예제
= 0.622 · = 0.0006284 m³ · = 235 N/mm² · = 1
= 91,853 Nm · Source: EN 1993-1-1:2005 식 (6.55)
Scope and standard
EN 1993-1-1 6.3.2.1에 따른 횡비틀림좌굴에 민감한 보.
- Standard
- EN 1993-1-1:2005, 6.3.2.1 (3) 절, 식 (6.55)
- Result
- in kN*m
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Matching CALC skillEurocode 3에 따른 단일경간 강재 보
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
설계 › 강재에서 검색이 시작됩니다.
Miaknows the formula catalog and asks for what is missing.